TM
Impulse
Operating and Maintenance Manual for:
ImpulseTM
Impulse VisionTM
Please read all operating instructions before using the ImpulseTM paintball marker.
100 Station Street • Loyalhanna, PA 15661
Telephone 724.539.2660 • Fax 724.539.2298
Electrical Power Supply
The Impulse is powered by a replaceable 9-volt battery. With normal care and usage, the battery
should last for approximately 25,000 shots. It is recommended that the Impulse be powered only by
alkaline batteries.
Propellant C02 / Compressed Air Supply
NOTE: We do not recommend the use of CO2 or compressed air systems that use a pin valve. If
your air system uses a pin valve, it is highly recommended that you use an inline on/off valve to
eliminate gassing and degassing problems.
The Impulse is capable of using either C02 gas or a compressed air system (nitrogen system). For
compressed air use it is required to use the Max-Flo regulator specifically designed to work on low
pressure markers. Please follow all instructions included for the air system being used on
your Impulse.
C02
To use your Impulse with C02, your bottle will need to have an anti-syphon tube that is correctly fit-
ted to the Impulse to prevent liquid C02 from entering the marker. If your C02 bottle does not include
an anti-syphon tube or your anti-syphon tube does not correctly position onto the marker, call a
certified airsmith to install one into your bottle. Do not attempt to disassemble a C02 bottle or install
an anti-syphon device.
Compressed Air
The compressed air system installed must be able to provide a high volume of air regulated at
150-200 psi. If the compressed air system installed cannot regulate to the required pressure, a
Max-Flo regulator will be required as a secondary regulator.
NOTE: Some of the steps below will require you to activate and fire the Impulse. Please read the
section on Operating the Impulse (page 4) before continuing with the compressed air installation.
1. Attach the air system to the Impulse.
2. Adjust the air system output pressure to below 100 psi (turn the Max-Flo spring
cap outward). This is to prevent the Impulse from being over-pressurized the first
time the air system is turned on.
3. Turn on the Impulse. By default it will activate in “Eye-Off Mode”. This is the
correct mode for initially setting the input air pressure, do not change.
4. SLOWLY turn on the air system and increase the input pressure to 150-160 psi.
For accurate adjustment, fire the marker, and readjust if necessary.
5. Attach the barrel and a loader. Put paintballs in loader.
6. Change the Impulse to “Eye-On Mode”.
IMPORTANT: In Eye-On Mode, the first shot will always fire with or without
a ball in the chamber.
7. Adjust regulator pressure between 150-200 psi to achieve desired velocity.
NOTE: If your Impulse is using a compressed air system and a secondary regulator, set the
output pressure of the primary air systems regulator to 650-750 psi. Follow Step 4 to set the
output pressure of the Max-Flo regulator.
[ 3 ]
Impulse Operating Instructions
The following section will review standard operating instructions for activating, deactivating and
mode selection for the Impulse.
Activating the Impulse
To turn on the Impulse, press and hold the power
button for 2 seconds. The power button is located on
the back of the solenoid housing. Upon activation the
Impulse will beep once and the LED light will display
a slow double blink. The Impulse is now active and in
Eye-Off Mode.
Impulse Power & Eye Mode Button
Power Button
& Eye Mode
Deactivating the Impulse
To turn off the Impulse, press and hold the power
button for 2 seconds. When deactivated, the Impulse
will beep once and the LED will not flash.
Auto Shut-Down Feature
If the Impulse is not fired for 20 minutes, it will automatically deactivate and not fire.
Low Battery Indicator
When the battery level of the Impulse drops below 6.8 volts, the marker will sound an audible
beep every 5 seconds.
Setting the Vision Eye Mode
The new Vision Eye detects the dropping motion of the paintball into the Impulse’s chamber.
With the Impulse in Eye-On Mode, it will only fire when a paintball has been detected by the
Vision Eye and is in the chamber ready to fire. With the Vision Eye turned off, the Impulse will
fire every time the trigger is pulled regardless of the position of the paintball.
To change Modes between Eye-On Mode and Eye-Off Mode, press the power button once to
switch back and forth between the two modes.
IMPORTANT: In Eye-On Mode, the first shot will fire with or without a paintball in the chamber.
This is to allow the Impulse to fire if a paintball was loaded into the chamber prior to the
marker being turned on.
LED Display for Vision Eye Modes
Eye-Off Mode Slow double blink every second. This is the default mode for the
Impulse when it is activated.
Eye-On Mode Rapid 5 blinks per second. Between shots, the LED will flash at 5 blinks
per second if the next paintball has successfully loaded. If the next paint-
ball has not correctly loaded, the LED will flash 1 blink per second until the
next paintball is loaded successfully.
[ 4 ]
Impulse Adjustments
The following section will review standard adjustment instructions for the Impulse.
Vision Eye
The new Impulse Vision Eye requires no manual adjustment. All settings are adjusted
automatically by the circuit board programming.
Rate of Fire
The new Impulse has two default fire rates that do not require adjustment:
Vision Eye Off: 13.7 shots per second
Vision Eye On: 20 shots per second
Input Pressure Adjustment
The input pressure adjustment is made to the Max-Flo regulator included with the Impulse. The
operating pressure should be set between 150-200 psi, depending on the velocity desired. Please
read the Max-Flo operating manual included with the Impulse.
Increasing the pressure on your regulator
1. Turn the spring cap inward (clockwise), while watching the input gauge.
2. Fire 3-5 shots and then chronograph the Impulse.
3. Adjust the regulator until you achieve the desired pressure.
Decreasing the pressure on your regulator
1. Turn the spring cap outward (counter clockwise), while watching the input gauge.
2. Fire 3-5 shots and then chronograph the Impulse.
3. Adjust the regulator until you achieve the desired pressure.
Once your regulator is set to the desired pressure, you can lock it down by tightening
the spring cap locking screw.
Dwell Adjustment
The dwell is the amount of time that the Impulse solenoid
valve remains open. This controls the amount of air sent
through the solenoid valve to the hammer. The dwell
setting can modify the velocity of the Impulse and the
marker should be chronographed after any adjustments
made to the dwell or input pressure.
Impulse Dwell Adjustment Buttons
Dwell
Down
Dwell
Up
The dwell has an operating range of 4-14 milliseconds which
is adjustable in .25 millisecond increments. The higher the
setting, the longer the valve stays open, thus increasing the
air flow to the hammer.
Increasing / Decreasing the Dwell - Using a small flat head tool press the Dwell Up or Dwell
Down Button located on the side of the solenoid housing. Each press adjusts the dwell up or down
.25 milliseconds and can be verified by a single high-pitch beep for each press. When the dwell
setting has reached the limit of its adjustment, a rapid low pitch beep will sound.
Resetting the Impulse Operating Pressures
First reset the dwell by pressing and holding the dwell down button until a low-pitch beep sounds.
The low pitch beep indicates that you have reached the bottom of the adjustment range for the
dwell. Next, adjust your Max-Flo to the desired input pressure (150-200 psi). Finally, increase the
dwell until the desired velocity is achieved.
[ 5 ]
Valve Assembly
[50] O-Ring (13/70)
[414] Bolt Pin
B
o
l
[49]
[411]
[49]
[5]
[546]
[407]
[70B]
[412]
t
[419] Aluminum Bolt
[46]
[413]
[Bolt]
[Body]
[49] O-Ring (18/70)
[411] Valve Seat
[46] O-Ring (10/70)
[413] Valve Seat Locator
[ 5 ] O-Ring (11/70)
[546] Delrin Valve
[Barrel]
[Hammer Assembly]
[407] Valve Spring
[70B] End Cap O-Ring
[412] End Cap
Vision Eye Assembly
[Valve End Cap]
[660]
[763]
[Valve Seat]
[737]
[655VF]
[Solenoid Housing]
[Vision Eye Assembly]
[Tapeworm (Optional Part)]
[Vertical Adapter]
[655UB]
[891]
[660]
[763]
[737]
Vision Eye Ball Detent
Vision Eye Cover
Vision Eye Screw
[655VF] Eye Flex Circuit
[655UB] Upper Board
[Grip Frame Screw]
Solenoid Housing Assembly
[Grip Frame Screw]
[891]
Upper Board Screw
[Grip Frame]
Hammer Assembly
[Gas thru Grip]
Button Housing (885)
Dwell Button Cap (893)
Power Button (883)
[410] Cylinder Cap
[48]
[46]
O-Ring (14/70)
O-Ring (10/70)
[Max-Flo Regulator]
[885]
[Max-Flo Vertical Regulator]
(optional part)
[883]
[885]
[406] Piston
[893]
[490] Piston Bumper
[405] Firing Cylinder
[231] O-Ring (9/70)
[Vertical Reg Bottom Line]
[893]
[49]
O-Ring (18/70)
[491] Actuator Bumper
[416] Bolt Actuator
[410]
[48]
[46]
[406]
[490]
[405]
[ 6 ]
[231]
[49]
[491]
[416]
[Solenoid Housing]
[ 7 ]
Max-Flo Vertical Regulator
Parts List & Assembly Guide
[44] O-Ring (15/70)
[397] Locknut GTS
[46] Impulse Vertical Nut
[536] O-Ring (20/70)
[209] Poppet Guide
[50] O-Ring (13/70)
[231] O-Ring (09/70)
[207] Spring Retainer
[211] Filter
[206] Poppet Spring
[205] Poppet
[203] Seat Cap
[233] O-Ring (09/90)
[204] Seat Base
[537] Set Screw
[46] O-Ring (10/70)
[762] 900 Swivel Macro Elbow
[37] 1/8” x 1/4” Plug
Max-Flo V-Reg Assembled
[464] Vertical Regulator Body
[232] O-Ring (03/90)
[540] O-Ring (14/75)
[532] Low Pressure Piston
[219] Spring Guide Pin
[227] Spring Guide
[230] Low Pressure Spring
[223] Bumper
[222] Filter Element
[774] Spring Cap Locking Screw
[640] Spring Cap